Skip to content
Articles

Scaling Semi-Solid Formulations: What Changes and What Must Stay the Same

Scaling Semi-Solid Formulations: What Changes and What Must Stay the Same

Scaling a semi-solid formulation from laboratory development to commercial manufacturing requires more than increasing batch size. The formulation Quality Target Product Profile (QTPP) and critical quality attributes (CQAs) must remain consistent, while certain process parameters need to be adjusted to account for changes in equipment, batch size, heat transfer, mixing, shear, and processing time.

For semi-solid drug products, those differences can affect emulsion stability, rheology, viscosity, particle or droplet size, homogeneity, drug release (IVRT), and other product characteristics. CPL approaches semi-solid scale-up by connecting formulation development, process development, analytical testing, equipment capability, and manufacturing from the early stages of development.

The Formulation Should Not Change During Scale-Up

A successful scale-up starts with a well-defined formulation strategy & planning.

The composition, raw material grades, QTPP and intended CQA should be established before a formulation moves into larger-scale manufacturing. Changing the formulation during scale-up can introduce variables that make it difficult to determine whether a difference in product performance is caused by the formulation or the manufacturing process.

Raw material selection also requires attention and critical material attributes (CMAs) must be established beforehand. Different grades or physical and chemical characteristics of an excipient can affect how a semi-solid behaves during processing. A material that performs adequately during laboratory development may not produce the same result if a different grade is introduced at larger scale.

Sponsors should therefore consider the eventual manufacturing requirements while selecting APIs and excipients and designing the initial formulation. The intended regulatory pathway, material specifications, product requirements, and commercial manufacturing strategy can all influence those decisions.

CPL evaluates these considerations as part of formulation development to help establish products that can transition from laboratory development to GMP manufacturing.

Scale-Up Changes the Process, Not the Target Product

The objective of scale-up is not to reproduce every laboratory process parameter at a larger numerical value. Some parameters are scale-dependent, while others need to remain fixed.

Composition and critical product attributes should remain consistent. Processing conditions such as mixing time, agitation, homogenization, heating, cooling, and vacuum may need to change because the manufacturing environment changes with scale.

A one-kilogram lab batch can behave differently from a 100-kilogram or 1,000-kilogram batch. The larger vessel or equipment has different geometry, heat-transfer characteristics, mixing patterns, shear rate and equipment capabilities. A process that works with an overhead mixer in a laboratory vessel may require sweep agitation, homogenization, or other equipment capabilities at manufacturing scale.

The challenge is determining which parameters need to change and how those changes can reproduce the same product characteristics.

Mixing and Emulsification Require Careful Scale-Up

Mixing is one of the most important considerations in semi-solid formulation scale-up.

Emulsion-based semi-solids require sufficient shear energy to combine phases and maintain the desired structure. The appropriate amount of shear, mixing speed, mixing time, and homogenization can change with equipment size and configuration.

A laboratory process may use high-speed mixing for a relatively small quantity of material. Applying the same approach without understanding how the equipment performs at larger scale can produce inadequate emulsification, excessive shear, aeration, alter the phase or other processing problems.

Emulsification can be particularly sensitive because the energy applied to the system influences characteristics such as droplet size and distribution. Those characteristics can affect the final product’s physical properties and performance.

CPL evaluates these relationships through process development and testing. Formulation behavior, rheology, microstructure, stability, and other product attributes can be evaluated alongside process parameters to establish a scalable manufacturing process.

Heating and Cooling Profiles Change With Batch Size

Temperature control is another area where laboratory conditions do not translate directly to commercial manufacturing.

A small laboratory batch can gain or lose heat quickly because of its relatively small volume and large surface-area-to-volume relationship. A larger manufacturing batch requires controlled heat transfer through the vessel and sufficient mixing to maintain temperature uniformity throughout the batch.

Heating and cooling profiles therefore may require different processing times or equipment settings at larger scale. The objective remains the same: achieve the required processing endpoint without changing the formulation or compromising the product’s CQAs.

This becomes especially important for semi-solids containing materials that must be melted, dispersed, hydrated, or otherwise processed within a defined temperature range.

Equipment Geometry Can Determine Scale-Up Success

Equipment selection is not simply a matter of choosing a vessel that can physically hold the desired batch size.

The relationship between batch size and equipment occupancy can affect mixing, flow, heat transfer, homogenization, and other process conditions. Running a relatively small batch in a vessel designed for a substantially larger batch can create its own challenges if the equipment is not operating within an appropriate working range.

Equipment geometry also matters. Laboratory vessels, pilot equipment, and commercial manufacturing vessels can have different dimensions and configurations. Mixing systems, sweep agitation, homogenizers, baffles, vessel walls, and other components can change how energy moves through the product.

CPL’s semi-solid manufacturing capabilities include pilot manufacturing from 20 kg to 300 kg and commercial manufacturing from 20 kg to 5,000 kg, along with temperature control, nitrogen blanketing, overhead mixers, homogenizers, and other equipment designed for semi-solid processing.

The appropriate equipment and operating range should be considered as part of process development rather than after the formulation has already been established.

Critical Process Parameters Connect the Process to Product Quality

Critical quality attributes define what the finished product needs to achieve. Critical process parameters (CPPs) help identify the manufacturing conditions that can influence those attributes.

For a semi-solid formulation, CPPs may include temperature, mixing speed, mixing time, homogenization conditions, shear, order of addition, and other unit-operation parameters.

CPL team identifies and studies these relationships during process development. In-process checks can help determine whether the process remains within the conditions needed to produce the intended product.

For example, a raw material may need to reach a defined temperature before proceeding to the next processing step. An emulsion may require a specific level of shear or homogenization. A polymer may require a particular dispersion process to prevent lump formation and achieve the required product characteristics.

These parameters need to be understood before commercial manufacturing rather than discovered during process validation or after launch. CPL uses formulation characterization, risk assessment, Design of Experiments (DoE), gap assessment and other process-development tools to define and understand the process conditions required for semi-solid products.

Pilot and Engineering Batches Provide Critical Scale-Up Information

Scale up and scale down calculations can provide a starting point for unit operation parameters. Factors such as tip speed, mixing conditions, homogenization speed, and other equipment characteristics can help establish an initial operating range.

Calculations alone, however, do not demonstrate that a process will produce the same product at larger scale.

Pilot and engineering batches provide an opportunity to test those assumptions. The resulting product can be evaluated against the laboratory formulation using measurable characteristics such as viscosity, specific gravity, pH, droplet size, microscopy, rheology and other applicable CQAs.

This intermediate work can identify whether a process needs more mixing, less shear, longer processing time, different temperature control, or another adjustment before the process moves into commercial manufacturing.

CPL incorporates pilot-scale and process-development work into its approach to scale-up, with the objective of establishing a reproducible process before commercial manufacturing.

Scale-Up Can Expose Problems That Were Hidden at Laboratory Scale

A process can appear robust in the laboratory and still reveal problems when batch size increases.

One example is polymer dispersion. A small quantity of polymer may be dispersed effectively using an overhead mixer. At larger scale, the same material may require additional homogenization or high-shear mixing to prevent lump formation and achieve uniform dispersion.

The opposite problem can also occur. Applying excessive shear at larger scale can alter the product rather than improve it.

The appropriate process therefore depends on the formulation, raw materials, equipment, batch size, desired product characteristics, and technical experience. Scale-up requires enough process understanding to determine where additional energy is needed and where additional energy could become detrimental.

This is why process observations made during laboratory development need to be documented and transferred into larger-scale development. Small processing details that appear insignificant at laboratory scale can become important when the same process is performed with kilograms or hundreds of kilograms of material.

Analytical Testing Confirms Whether Scale-Up Worked

Scale-up decisions should be supported by data.

For semi-solid formulations, applicable testing can include viscosity, specific gravity, pH, microscopy, rheology, particle or droplet size, assay, content uniformity, stability, drug release, and other product-specific measurements. CPL also provides IVRT and IVPT capabilities for applicable topical and semi-solid products.

In-process testing can provide information before a batch is completed. For example, pH and viscosity measurements can help confirm that a formulation is progressing toward the intended product characteristics. Microscopy can provide information about microstructure and globule size for applicable emulsion systems.

IVRT can also provide a quantitative way to compare drug release between batches and assess whether changes in manufacturing scale or process conditions have affected product performance. IVPT can provide additional information about drug permeation and distribution within the skin when applicable to the development program.

The objective is to establish that the larger-scale process produces a product consistent with the predefined CQAs.

Designing for Scale Starts During Formulation Development

Commercial scale-up should influence formulation development from the beginning.

Sponsors should consider the intended product type, regulatory pathway, API and excipient characteristics, material specifications, process requirements, equipment capabilities, and eventual commercial batch size while developing the laboratory process.

A process that is easy to perform with a few grams of material may require significant modification when the same operation involves kilograms or hundreds of kilograms. Designing with manufacturability in mind can reduce the need for late-stage reformulation or process changes.

CPL connects semi-solid formulation development with manufacturability, process development, analytical testing, technology transfer, and GMP manufacturing. The objective is to develop formulations that perform in the laboratory and can transition into reproducible manufacturing.

A Structured Approach Reduces Scale-Up Risk

Moving directly from laboratory development to the largest possible manufacturing batch can leave important process questions unanswered.

Pilot batches, engineering studies, process characterization, analytical testing, and technology transfer provide opportunities to establish how the formulation behaves at increasing scale. Skipping those steps can shift unresolved process risks into validation or commercial production.

CPL’s technology transfer process includes structured gap and risk analysis, laboratory and pilot batches, scale-up studies, CPP and CQA assessments, and process validation activities. This approach helps identify differences between development and manufacturing before they become commercial manufacturing problems.

The goal is to establish a process that is understood, reproducible, and appropriate for the intended manufacturing scale.

Scale Semi-Solid Formulations With CPL

Successful semi-solid formulation scale-up requires a clear understanding of what must remain fixed and what must change. The formulation composition and CQAs should remain consistent. Process parameters may need to change as batch size, equipment geometry, heat transfer, mixing, shear, and processing conditions change.

CPL brings specialized experience in semi-solid formulation development, process development, scale-up, analytical testing, technology transfer, and GMP manufacturing. With pilot manufacturing capabilities from 20 kg to 300 kg and commercial manufacturing capabilities up to 5,000 kg, CPL can evaluate formulation and process requirements across development stages and establish processes designed for commercial manufacturing.

Sponsors developing a new semi-solid formulation or preparing an existing product for larger-scale manufacturing can contact CPL to discuss formulation development, manufacturability, scale-up, or technology transfer requirements. Schedule a meeting with CPL to evaluate the path from laboratory formulation to reliable commercial production.

Partner with CPL

Have questions about this topic or want to discuss your project? Our team is here to help.

Service of Interest

You can unsubscribe from these communications at any time. For more information on how to unsubscribe, our privacy practices, and our commitment to protecting and respecting your privacy, please review our Privacy Policy.

By clicking submit below, you consent to allow CPL to store and process the personal information submitted above.

Required Fields